★ Procedure Library ★

Worked examples of
real isolation procedures.

Twelve equipment-specific lockout/tagout procedures across twelve industries, with the actual isolation-point structure each one needs. Free to read, free to download, no signup. They are examples to learn from — not documents to adopt.

What makes these useful

Lockout is equipment-specific. So are these.

A generic checklist tells you to isolate, lock, tag and verify. It cannot tell you that a wind turbine's pitch UPS must stay live so the blades can be feathered, that a converter DC link holds stored energy after the grid disconnect opens, or that blade lightning receptors cannot be isolated at all. Each example below distinguishes the points you isolate from the points you must leave alone — because on real plant, that difference is the procedure.

Semiconductor
PE-2200 Etch Chamber A — Wet Clean Isolation

Full energy isolation of plasma etch chamber A for scheduled chamber wet clean. Cl2/BCl3 metal etch chemistry.

10 isolation points
Mining & aggregates
CR-101 Primary Crusher — Mantle Change Isolation

Full isolation of CR-101 for mantle change. Includes upstream CV-200 feed conveyor isolation per interlock requirement.

10 isolation points
Automotive manufacturing
RC-14 Robot Weld Cell - Weld Tip Change Isolation

Full energy isolation of RC-14 for weld gun tip change and reamer service. Entry into the cell.

11 isolation points
Food & beverage
FL-3 Filler - Capper Head Service and Bowl Entry

Capper head rebuild plus filler bowl internal inspection. Includes DP-1 depalletizer isolation and CO2 purge.

13 isolation points
Drilling
RIG-27 Rig Down for Relocation

Full rig de-energisation prior to rig down and move. Spans SCR house, drawworks, top drive, mud pump, BOP and mast. Multi-shift.

18 isolation points Other standards apply
Amusement & attractions
RC-01 Thunderbolt — LSM Cabinet Service

Launch track LSM cabinet service. Includes transfer track isolation and capacitor bank discharge. ASTM F770 maintenance.

12 isolation points Other standards apply
Rail
Possession — Down Main MP12.4 to MP15.8

Absolute possession of the Down Main for engineering work. PICOP-controlled. Includes 25kV OLE isolation and earthing.

10 isolation points Other standards apply
Aviation MRO
AMM 27-51 — Trailing Edge Flap Actuator Replacement

B737-800 flap actuator change. ALL THREE hydraulic sources must be isolated - the flight controls are redundantly driven.

13 isolation points Other standards apply
Ropeway & tramway
TRAM-1 — Haul Rope Inspection and Sheave Change

Annual haul rope inspection with tower sheave assembly change. ANSI B77.1. Evacuation drive must remain available throughout.

11 isolation points
Wind energy
WTG-07 Gearbox Inspection and Hub Entry

Nacelle gearbox inspection with hub entry for pitch bearing check. Rotor lock mandatory before hub entry.

12 isolation points Other standards apply
Water & wastewater
MUD-T2 Confined Space Entry - Tank Clean and Inspect

Permit-required confined space entry into mud tank no.2 for cleaning and internal inspection. 29 CFR 1910.146.

12 isolation points Other standards apply
Tank & terminal
TK-401 Nozzle Weld Repair - Hot Work

Weld repair to the 6in outlet nozzle on TK-401. NFPA 51B hot work. Fire watch 30 minutes after work stops.

10 isolation points Other standards apply
Before you use anything here

These are examples. Your procedures are yours.

Under 29 CFR 1910.147(c)(4)(i) the employer must develop, document and use energy control procedures specific to their own machines, and under (c)(6) must inspect them at least annually. A vendor cannot take on that duty and a customer cannot delegate it. Every example here refers to equipment that does not exist, and each one deliberately omits the site-specific facts only you can supply.